Implant Placement Surgery for Tooth #47
Implant Placement
Implant Placement

Chief Complaint
Patient requires replacement for the missing tooth #47.
Clinical Findings
Missing tooth #47
Treatment Plan
Discussed risks, procedures, and alternatives for replacing tooth #47
Pre-operative CBCT reviewed
Patient understood and agreed to proceed
Informed consent obtained for implant placement surgery on the #47 site
Pre-operative Assessment
Anesthesia
LA block: right inferior dental nerve (IDN), lingual nerve (LN), and long buccal nerve (LBN)
Surgical Procedure
Patient cleaned and draped
Incision made, buccal flap raised
Implant site prepared
Mid-operative CBCT taken to confirm implant position and alignment of the preparation
Final preparation of the implant site after confirming alignment
5.0mm x 8.0mm Dentium Superline II implant placed
6.5mm (small) healing abutment placed
Occlusion checked
Bioactive synthetic scaffold (BSS) placed x4 for primary closure
Hemostasis achieved, post-operative instructions given
Post Operation Gallery
![]() | ![]() | ![]() |
---|---|---|
![]() | ![]() | ![]() |