top of page

Implant Placement for #12

Implant Placement

Chief Complaint

Patient requires an implant for the replacement of missing tooth #12.

Clinical Findings

CBCT reviewed for implant planning.

Risks and procedures explained to the patient.

Implant position planned and approved by the patient.

Treatment Plan

Implant placement at site #12.

Bone grafting to support the implant.

Pre-operative Assessment

CBCT reviewed to assess bone structure and implant positioning.

Informed consent obtained for the implant placement procedure.

Anesthesia

Local anesthesia administered.

Surgical Procedure

  1. Patient cleaned and draped.

  2. Incision made and buccal flap raised.

  3. Implant sites prepared with implant drills and osteotomes.

  4. 3.6mm x 12.0mm Superline III implants placed.

  5. Healing abutment (6.5mm diameter, M size) placed.

  6. Bone grafting performed with 6.0mm x 10.0mm Dentium Osteon II collagen artificial bone grafting material.

  7. Buccal flap released.

  8. 5/0 BSS x 10 placed for primary closure.

  9. Hemostasis achieved.

Post-operative Assessment

Post-operative CBCT taken.

Implant alignment and position confirmed as good.

Bone graft integration appears dense.

Patient satisfied with the procedure.

bottom of page